Shunt active power filter for harmonic compensation of two-phase nonlinear loads.

A new topology for a two-phase shunt active power filter using a voltage source converter is proposed. The converter is controlled with a predictive control algorithm based in a discrete mathematical model of the system which allows to minimize the quadratic error between the lines currents and the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor Principal: Restrepo Zambrano, Jos? Alex
Formato: Artículos
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://repositorio.educacionsuperior.gob.ec/handle/28000/3867
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:localhost:28000-3867
recordtype dspace
spelling oai:localhost:28000-38672017-04-13T15:13:26Z Shunt active power filter for harmonic compensation of two-phase nonlinear loads. Restrepo Zambrano, Jos? Alex MATHEMATICAL MODEL POWER CONVERSION TOPOLOGY A new topology for a two-phase shunt active power filter using a voltage source converter is proposed. The converter is controlled with a predictive control algorithm based in a discrete mathematical model of the system which allows to minimize the quadratic error between the lines currents and the reference currents. The whole system is tested with simulations and with a prototype experimental setup, showing its effectiveness in the compensation of current harmonics produced by two-phase nonlinear loads. https://www.researchgate.net/publication/265728300_Shunt_active_power_filter_for_harmonic_compensation_of_two-phase_nonlinear_loads 2017-04-12T17:59:38Z 2017-04-12T17:59:38Z 2014 article Bueno, H?ctor. et al. (2014). Shunt active power filter for harmonic compensation of two-phase nonlinear loads.Transmission & Distribution Conference and Exposition - Latin America (PES T&D-LA). Italia. http://repositorio.educacionsuperior.gob.ec/handle/28000/3867 eng DOI;10.1109/TDC-LA.2014.6955204 closedAccess http://creativecommons.org/licenses/by-nc-sa/3.0/ec/
institution SENESCYT
collection Repositorio SENESCYT
biblioteca Biblioteca Senescyt
language eng
format Artículos
topic MATHEMATICAL MODEL
POWER CONVERSION
TOPOLOGY
spellingShingle MATHEMATICAL MODEL
POWER CONVERSION
TOPOLOGY
Restrepo Zambrano, Jos? Alex
Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
description A new topology for a two-phase shunt active power filter using a voltage source converter is proposed. The converter is controlled with a predictive control algorithm based in a discrete mathematical model of the system which allows to minimize the quadratic error between the lines currents and the reference currents. The whole system is tested with simulations and with a prototype experimental setup, showing its effectiveness in the compensation of current harmonics produced by two-phase nonlinear loads.
author Restrepo Zambrano, Jos? Alex
author_facet Restrepo Zambrano, Jos? Alex
author_sort Restrepo Zambrano, Jos? Alex
title Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
title_short Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
title_full Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
title_fullStr Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
title_full_unstemmed Shunt active power filter for harmonic compensation of two-phase nonlinear loads.
title_sort shunt active power filter for harmonic compensation of two-phase nonlinear loads.
publishDate 2017
url http://repositorio.educacionsuperior.gob.ec/handle/28000/3867
_version_ 1634995197638082560
score 11,871979