Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations

In this project, the operation and performance of the three-leg VSI control and the four-leg VSI control are studied for grid connected applications and for autonomous operation .The voltage source inverters are modelled and simulated in the stationary frames Alpha-Beta and AlphaBeta-Gamma in order...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor Principal: Frutos Galarza, Paul Alejandro
Otros Autores: Arthur, Williams
Formato: Tesis de Maestría
Lenguaje:eng
Publicado: Reino Unido /University of Nottingham / 2016 2017
Materias:
Acceso en línea:http://repositorio.educacionsuperior.gob.ec/handle/28000/4252
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:localhost:28000-4252
recordtype dspace
spelling oai:localhost:28000-42522017-06-10T08:02:23Z Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations Frutos Galarza, Paul Alejandro Arthur, Williams MODULATION CURRENT CONTROL VOLTAGE CONTROL POWER QUALITY In this project, the operation and performance of the three-leg VSI control and the four-leg VSI control are studied for grid connected applications and for autonomous operation .The voltage source inverters are modelled and simulated in the stationary frames Alpha-Beta and AlphaBeta-Gamma in order to perform the system control action employing proportional resonant compensators. The simulations are performed in PLECS that can be used standalone or integrated with MATLAB/Simulink. The three-dimensional space vector modulation technique is implemented as a C-script for the control action of the four-leg VSI. Furthermore, the independent control of each voltage phase at the point of common coupling for standalone operation using the four-leg VSI topology is implemented in a stationary frame to deal with balanced and unbalanced loads in order to improve the power quality that is sent to the AC system. 2017-06-09T19:47:06Z 2017-06-09T19:47:06Z 2016-12 masterThesis Frutos Galarza, Paul Alejandro, (2016).Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations. (Trabajo de titulaci?n de la Maestr?a en Ingenier+ia El?ctrica). University of Nottingham. Reino Unido. 80p. http://repositorio.educacionsuperior.gob.ec/handle/28000/4252 eng Reino Unido /University of Nottingham / 2016
institution SENESCYT
collection Repositorio SENESCYT
biblioteca Biblioteca Senescyt
language eng
format Tesis de Maestría
topic MODULATION
CURRENT CONTROL
VOLTAGE CONTROL
POWER QUALITY
spellingShingle MODULATION
CURRENT CONTROL
VOLTAGE CONTROL
POWER QUALITY
Frutos Galarza, Paul Alejandro
Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
description In this project, the operation and performance of the three-leg VSI control and the four-leg VSI control are studied for grid connected applications and for autonomous operation .The voltage source inverters are modelled and simulated in the stationary frames Alpha-Beta and AlphaBeta-Gamma in order to perform the system control action employing proportional resonant compensators. The simulations are performed in PLECS that can be used standalone or integrated with MATLAB/Simulink. The three-dimensional space vector modulation technique is implemented as a C-script for the control action of the four-leg VSI. Furthermore, the independent control of each voltage phase at the point of common coupling for standalone operation using the four-leg VSI topology is implemented in a stationary frame to deal with balanced and unbalanced loads in order to improve the power quality that is sent to the AC system.
author2 Arthur, Williams
author_facet Arthur, Williams
Frutos Galarza, Paul Alejandro
author Frutos Galarza, Paul Alejandro
author_sort Frutos Galarza, Paul Alejandro
title Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
title_short Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
title_full Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
title_fullStr Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
title_full_unstemmed Stationary Frame Control of Three-leg and Four- Leg and Four -Leg Voltage Source Inverters in Power System applications: modelling and Simulations applications: modelling and Simulations
title_sort stationary frame control of three-leg and four- leg and four -leg voltage source inverters in power system applications: modelling and simulations applications: modelling and simulations
publisher Reino Unido /University of Nottingham / 2016
publishDate 2017
url http://repositorio.educacionsuperior.gob.ec/handle/28000/4252
_version_ 1634995233061076992
score 11,871979